MODEL CLASSROOM DESCRIPTIONS AND REQUIREMENTS
INDIANA UNIVERSITY, BLOOMINGTON
©Indiana University
For permission to use this document or for further information, please contact:
Beverly Teach, Chair
All Campus Classroom Committee
Instructional Support Services
601 E. Kirkwood/Franklin Hall 0003
Bloomington, IN 47405-1223
INSTRUCTIONAL AREAS
DESCRIPTION
Project Booth, Small
12 assignable square feet
DEFINITION
A small enclosed space near the rear of the classroom that can house equipment securely and from which projection equipment can be operated. It is not large enough to provide workspace for a technician, but instead is constructed with enough space behind it so that an access door can be located there and a technician can reach into the space to set up or adjust equipment.
WEB LINKS
For those who are accessing this material on the Internet, the following links are available:
SPECIAL ROOM REQUIREMENTS
IU
Building Design Standards
Architectural
IU
Engineering Standards
Mechanical
Extend HVAC to Projection Booth with independent thermostat or thermostatically controlled exhaust fan or vent
Introduce supply air low and remove exhaust air high
Provide cooling for current equipment array and allow for expansion of cooling required to double current output
IU
Engineering Standards
Electrical
Conduit Requirements
2 conduit from junction box in Media Equipment Closet (MEC) to Projection Booth per projector
(2) 1 ½ from junction box in MEC to Projection Booth, landed in a series of (3) 3 gang junction boxes mounted vertically on the wall of the booth above the projection shelf. Connect second 3 gang box to first with (2) 1 ½ conduits, connect third 3 gang box to second with (1) 1 ½ conduit. Depending on individual circumstances, 3 gang boxes may be mounted horizontally.
Ύ from junction box in MEC to Projection Booth, landed in a separate single gang box for slide projector and AMX controls (optional)
Ύ from junction box in MEC to Projection Booth, for lighting control scene controller
½ conduit from junction box in MEC for relay solenoid control door lock (optional)
1 from audio junction box in MEC to a separate junction box in Projection Booth for speaker wires, landing in a 3 gang box on wall of projection booth. Conduit size to be reviewed for zoned system voice reinforcement.
Lighting
Dimmable light with independent control
Lighting control scene controller for classroom
Master programming controller for architectural dimming system may be located in projection booth only if it is separated from the dimming control panel. If the master programming controller and the dimming panel are integrated, the unit shall not be located in the projection booth but in the Electrical Equipment Closet or some other isolated location near the classroom [In most cases, this projection booth will be too small to house the programming controller.]
Audio
Provide line level sound jack in booth for 16mm film projection
Power
Telecommunications
Install pathway according to IU Telecommunications Standard and specific campus addendums to bring voice, data, video coax, and fiber from source outside room (IDF closet) to a standard communications outlet in Projection Booth
Provide one data jack at each projector location (optional)
EQUIPMENT REQUIREMENTS
Following is a representative, generic list of classroom technology items; specific selections shall be made from the Approved Technology Listing.
Video Projector(s)
35 mm slide projector (optional)
16 mm projector (optional)
Video camera (optional)
LOCATION REQUIREMENTS
Locate at rear of classroom with space behind to provide workspace for technician.